HOME>LEARNING>How to Check for Window Reflections in a 3–5 µm Thermal Camera

How to Check for Window Reflections in a 3–5 µm Thermal Camera

  • 25/11/2026
  • SHARE TO:

A small hot target shows up where it should. A second, dimmer patch appears a short distance away. Before changing the camera’s calibration, find out whether that patch moves with the target and whether it depends on the external window. A 3–5 µm thermal camera can receive a second image of a source after part of the light bounces between optical surfaces. A window that passes plenty of light can still be involved.

Run the comparison on a removable external window or on a spare mounted in a test fixture. Keep sealed camera assemblies intact. A suitable bench setup gives you access to the window without disturbing the camera lens or its detector package.

How to Check for Window Reflections in a 3–5 µm Thermal Camera

Establish that the extra image depends on the window

Move a compact target across a steady background

Use a small, stable thermal target against an even background. Keep the target signal below saturation so both image peaks can be compared. First place the target near the middle of the field. Then step it toward two different edges and save a frame at each position. Keep lens focus, integration time, gain, display span and any image corrections fixed where the camera allows. Record the settings if the camera applies a correction automatically.

A real reflection can produce a soft copy or a recognizable part of the target. The copy may change position, size or sharpness as the target moves. Mark the position of each feature in the saved frames. If a mark stays on the same pixels as the target moves, investigate a fixed pattern or something in the scene before blaming the window. This is a screening observation. More than one artifact can be present in a single frame.

Compare frames with and without the external plate

Use the same target positions and capture a second set with the external plate out of the beam. Where possible, keep the rest of the fixture in place so that its reflections and shading stay comparable. The camera should have settled before recording either set. If taking the plate out changes focus or throughput, note that change and compare the extra feature with the main image under each condition. A window can participate in a reflection elsewhere in the optical train, so disappearance of the ghost implicates the window without identifying a specific face.

If the housing or another hot object comes into view when the plate is moved, reset the background before judging the two frames. A change in apparent background can obscure the faint patch. Save the raw radiometric signal or linear image data if available. A color palette can make the same small signal difference look much larger when its span changes.

A simple trial works best with a small number of frames you can line up afterward. At each target position, write down the pixel coordinates of the main image and the suspected copy. If you have a spare window, mark the orientation of the installed one before swapping it out. That saves an extra run if the comparison points to the plate and you need to recreate the original orientation.

Work out how the light returns to the camera

Two bounces within the window

The direct beam crosses both faces and heads toward the lens. A weaker part reflects off the rear face, returns to the front face and reflects again. It can then leave the plate in the same general direction as the direct beam. At oblique incidence in a parallel plate, the returning bundle can emerge laterally displaced. Whether the camera forms a separate patch depends on where the plate sits and how the downstream optics image that bundle. The ETH Zurich optics lab notes illustrate the direct and internally reflected paths through a parallel plate.

One bounce at the window and one inside the camera

Light that cleared the window can reflect back toward it from a lens surface or a cover near the detector. The window then sends part of that return into the camera again. Here the window acts as one surface of a longer path. Changing the gap or tilt in a test fixture may change the ghost’s position or how well it is focused. Optical modeling can help distinguish surfaces when several paths give similar-looking images. University of Arizona notes on optical ghost images describe how specular surface reflections produce secondary images.

mwir-window-reflection-paths

Choose a change that addresses the identified path

Lower the reflected signal

An antireflection coating changes how much radiation returns from a surface over the intended wavelength range. BoDian Optical develops infrared antireflection components as part of its thin film product range. Its IAR3000-5000 infrared antireflection filter is a silicon option for the 3–5 µm range. The published average transmittance is at least 95% over 3000–5000 nm. That figure describes light transmitted through the component. For a particular return path, ask for reflectance data for the faces it encounters.

BoDian can customize the wavelength, dimensions and film design and process parts to a supplied drawing or sample. For this job, put the operating band and angular range next to the coating callout. Identify the scene side and the camera side on the drawing so the supplier can tell which surface needs the reflectance limit. If one number must govern acceptance, name the quantity explicitly. An average transmission value and an upper bound for reflection over a stated band answer different questions.

Move the reflected bundle

Try a small controlled tilt in a fixture with a spare plate. Keep the lens and target stationary while changing the tilt by a known amount. If the copy moves toward the edge, confirm where it lands when the target visits all the required field positions. It may leave the frame at the center test position and reappear at a corner. Tilt can also affect the useful beam and change the angle at which it sees the coating. Check the new position across the operating field before freezing the mount.

A wedged plate can steer a reflection differently from a tilted parallel plate. It can steer the main beam too. Before ordering one, use the actual placement and thickness to check boresight and where the returned bundle travels. The observation that a ghost moves with tilt gives the designer a lead to follow. The final geometry still needs to pass the camera’s alignment and image checks.

IAR3000-5000Infrared anti reflection filter

Confirm the change on the camera

Compare Ghost Images Before and After the Change

Replay the same target positions after the change and match the exposure and display settings from the baseline. Compare the extra patch with its local background and the primary image. Specify the acceptable residual in the data the camera can actually deliver. Keep the target size, signal level and measurement regions in the acceptance record so the next unit can be checked under comparable conditions.

Check the Replacement Window’s Dimensions and Surface Quality

For a replacement plate, agree on dimensional and surface acceptance at the same time as the coating requirement. BoDian checks size and tolerance with calipers and micrometers and uses visual inspection or microscopy for surface quality. A double polished plate needs inspection for chips or cracks at the edges as well as checks on its main faces. If the new plate returns a weaker ghost but no longer seats squarely, those physical inspection results are useful when comparing it with the original.

Verify Infrared Transmission and Reflection Performance

BoDian uses spectrometers to measure transmittance, reflectance and absorbance of thin film optics, including infrared components. The transmission and reflection measurements can be requested across the working band. Absorbance is another available measurement when the part’s own losses need checking. Ask for the traces separately if the ghost and the primary image both changed. The reflectance trace is relevant to the unwanted return, while the transmission trace helps interpret the level of the main image with the new part in place. The Spectrum 3 is among its infrared measuring instruments. BoDian’s coating equipment includes evaporation and magnetron sputtering systems, and its thin film inspection capability covers ultraviolet, visible and infrared measurements. For a window that works only in the 3–5 µm band, call out that band explicitly for the infrared measurement. A spectral test report documents the component under the agreed test conditions. Pair the relevant transmission and reflection traces with the before-and-after camera frames. If the reflection report measures the whole part instead of an individual face, record that distinction. The window and the assembled camera each have a check to pass.

Send the Window Specifications and Test Results to the Supplier

For help specifying a replacement,  send the window drawing and comparison frames. The most helpful pair shows a ghost at a fixed target position with the window installed and the same frame with the plate removed. Include the operating band and the range of angles at the window. Those details give the coating supplier somewhere concrete to start.