HOME>LEARNING>Why an IR Bandpass Filter Can Cause Vignetting After Mounting

Why an IR Bandpass Filter Can Cause Vignetting After Mounting

  • 26/11/2026
  • SHARE TO:

The center of the inspection image looks fine. One corner goes dark as soon as the filter holder is installed. Take a look at the opening in the retaining ring before asking for a different coating. An IR bandpass filter can pass the beam on axis and still lose part of the bundle headed for a corner. The edge of the coated area can also cut into that bundle, even when the glass itself is large enough.

A useful first question is where the beam gets closest to an edge. A ring at the front of a deep mount and a shoulder behind the filter sit at different distances from the lens. Each needs room for the bundle where it actually crosses that surface. Checking only the diameter of the filter leaves both of those openings unaccounted for.

Why an IR Bandpass Filter Can Cause Vignetting After Mounting

Three dimensions that matter at the filter

Outside diameter and optical clear aperture

The outside diameter tells the machinist whether the disk fits the seat. The clear aperture tells the optical designer where the specified performance applies. The two dimensions can differ because of a bevel, an edge exclusion for coating, or the way the part is held during deposition. If a drawing separates the coating area from the clear aperture, carry both dimensions through the design review. The area that looks coated under a lamp can extend beyond the area guaranteed to meet the spectral requirement.

BoDian Optical makes infrared thin film filters in different sizes and shapes and can adjust the optical aperture to suit the part requirements. A drawing can specify the outside diameter and its tolerance, thickness, usable optical aperture and the required surface finish. Dimensional checks with calipers or micrometers cover physical dimensions such as size and thickness. A visual or microscope check addresses surface and edge condition. On a polished part, chips or cracks near the usable area deserve their own disposition even when the outside diameter measures within tolerance.

The opening left by the hardware

The seat, retaining ring and any spacer each leave a physical opening. A centered ruler measurement across the front of the assembly can miss an obstruction at the back. A thick ring may also limit rays farther from the filter face because the oblique bundle walks sideways along the bore. View the assembly in section and mark the openings on both ends of any bore with appreciable depth.

The University of Arizona notes on vignetting show what happens when an aperture cuts away part of an off-axis ray bundle. In a camera with a rectangular sensor, include the diagonal field in the ray check. A pass at the midpoint of the sensor’s long edge can leave the corner untested.

Calculate the clearance where the rays cross each opening

Check the ring and the filter in separate planes

Ask for the ray footprint at the installed filter, ring and shoulder. With a circular opening and a roughly circular bundle, add the maximum likely offset of the bundle center to the footprint radius. Then allow for the amount by which assembly tolerances can move the opening relative to the bundle. Compare the sum with the minimum available radius on the hardware drawing. If the footprint is elongated, check the actual outer rays. The radius of a circle fitted to the middle of the bundle can miss a corner of that footprint.

Use the far face of a tall ring as a separate plane. Its clearance can differ from that of the face next to the glass. The worst mounting tolerance may also occur along a different direction from the nominal field offset. Adding offsets in the same direction is a conservative screening calculation. A ray trace with the real dimensions and assembly tolerances can refine the result before tooling.

A 25 mm disk with a tight rear opening

Consider a hypothetical disk with a 25 mm outside diameter and a guaranteed 22 mm clear aperture. At the coated surface, a corner field has an 8.6 mm footprint radius and a 1.7 mm center offset. Allow another 0.3 mm for relative decenter. The required radius is 10.6 mm, which leaves 0.4 mm inside the guaranteed 11 mm radius.

At the rear ring, the modeled footprint radius is 8.8 mm and the center offset is 2.0 mm. With the same 0.3 mm allowance, that plane needs 11.1 mm in radius. A minimum bore of 21 mm leaves only 10.5 mm. The shortfall is 0.6 mm at the worst edge. A nominal 22.2 mm bore leaves no allowance for undersize machining. The drawing needs a minimum bore and an allowance for any additional uncertainty the model leaves out.

ir-filter-mounted-clearance

Find the cause on the inspection bench

Start with a uniform target and a baseline frame from the camera without the suspect assembly. Lock exposure, gain and any shading correction. Keep the lens, lighting, distance and focus fixed. If the filter shifts the overall signal, compare the shape of the field response after accounting for that level change. A corner that drops relative to the center after installation is worth investigating. A large loss across the entire field calls for a look at the source and detector bands as well.

An approved larger-opening holder can help isolate the original ring or shoulder. Repeat the shot with the same filter and as close as possible to the same location and tilt. A corner that recovers after the opening is enlarged gives you a direct reason to revisit the mount. If the same dark area remains, inspect the coated aperture and check the ray footprint against the filter drawing. Compare raw images before any flat-field correction. The correction can hide the loss in brightness while the underlying loss of signal remains.

Mechanical inspection and spectral performance measurements address different parts of that diagnosis. BoDian can measure transmission, reflectance and absorbance of thin film filters with spectrometers covering ultraviolet, visible and infrared bands. The laboratory equipment includes the Cary 5000, Cary 7000 and Spectrum 3. When a replacement disk has to cover a particular infrared band, send that interval with the dimensional drawing so the spectral and physical inspection requests describe the same part. An infrared transmission trace documents the filter response for the bench setup used to acquire it. Keep that trace alongside the mounted camera images and dimensional results. The images preserve where in the field the loss occurred, while the trace preserves the wavelength range and optical response of the sample.

Put the part and assembly requirements on the drawings

Place the guaranteed clear aperture on the part drawing and identify the surface or surfaces to which it applies. Specify how the aperture is centered on the disk. On the assembly drawing, label the minimum opening at each limiting face, the seat depth and the relationship of the bore to the camera’s optical axis. If the designer intends a coating callout to apply over a defined area, make that boundary explicit. ISO 10110-9 on surface treatment and coatings covers the presentation of coating requirements on optical drawings.

The infrared narrow bandpass filter range is a starting point once the wavelength requirement is known. BoDian can vary wavelength, part size and film design for custom work, including orders based on a customer drawing or sample. The shop can work with incoming material as well. That matters when a disk has already been made and only the coating is being changed. The supplied blank fixes the outside dimensions. The optical aperture and film design can still be discussed with the coating shop while the mount opening is resolved separately. A polished sample from the current build can accompany the drawing so the quoted part and the installed part refer to the same geometry.

infrared narrow bandpass filter range

Give the filter supplier the optical aperture requirement along with the passband and blocking limits. Give the mount supplier the minimum free opening and the location of the opening relative to the filter. A diameter on the lower-level part drawing gives neither supplier a view of how the neighboring part can eat into the available margin.

Before the drawing is released, mark the worst field footprint on the section and show where the mount comes closest to it. Send the filter drawing and mount section together for review. If the camera is already on the bench, attach the original and larger-opening-holder frames. Those two pictures help pin down which dimension is worth changing.